Proven Wind Generator Products |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11 mile per hour = 13.6 kph = 0.45 metre/second. All readings taken with an ATP SL-25 dBA meter at the base of the
Data SheetProven 6kW
The Proven 6 produces 6kW of electricity. It is able to meet the power needs of a standard house with four to six bedrooms, excluding heating. Any excess energy production can be stored or exported to the grid, depending on local regulations. Features
Technical Specifications
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cut In (mph) 1 : |
5 |
Cut Out (mph): |
None |
Survival (mph): |
156 |
Rated (mph): |
27 |
Rotor Type: |
Downwind, self regulating |
Number of Blades: |
3 |
Blade Material: |
Thermoplastic glass composite |
Rotor Diameter (ft): |
18 |
Generator Type: |
Brushless, direct drive, permanent magnet |
Battery Charging: |
48V DC |
Grid Connect with Windy Boy Inverter: |
230 Vac 50 Hz or 24 Vac 60 Hz |
Direct Heating: |
240 Vac |
Rated RPM: |
200 |
Annual Output 2 : |
6,000-12,000 kWh |
Head Weight (lbs): |
1,323 |
Mast Type: |
Tilt-Up, tapered, self-supporting, no guy wires |
Hub Height (ft): |
30 ft or 49 ft (taller towers also available upon request |
WT Found (yd 3 ): |
8 or 14 |
Winch Found (yd 3 ): |
1.3 or 3 |
Tower Weight (lbs): |
794 or 1,446 |
Mechanical Brake: |
Yes |
| Noise 3 @ 11 mph*: | 45 dBA |
| Noise @ 45 mph*: | 65 dBA |
| Rotor Thrust (kN): | 10 |
11 mile per hour = 13.6 kph = 0.45 metre/second.
Annual Output 2 range is quoted to cover typical average wind speeds (annual).
Lighter wind sites with typical 10 mph will produce lower end of range.
Higher wind speed sites, e.g., 13.5 mph average will produce upper end of range.
All readings taken with an ATP SL-25 dBA meter at the base of the
tower at a height of 5 ft.
*A car passing 65 ft away @ approximately 40 mph is 70-80 dBA.
The Proven 15 is ideal for commercial applications, including agriculture, telecoms applications, small industrial units and mini wind farms.
Grants and funding for installation are widely available for consumers and businesses. Generating electricity from a wind turbine helps to cut down CO2 emissions and reduces climate change levy charges.
Technical Specifications
Cut In (mph)1: |
5 |
Cut Out (mph): |
None |
Survival (mph): |
156 |
Rated (mph): |
27 |
Rotor Type: |
Downwind, self regulating |
Number of Blades: |
3 |
Blade Material: |
Thermoplastic glass composite |
Rotor Diameter (ft): |
29.5 |
Generator Type: |
Brushless, direct drive, permanent magnet |
Battery Charging: |
48V DC |
Grid Connect with Windy Boy Inverter: |
230 Vac 50 Hz or 24 Vac 60 Hz |
Rated RPM: |
150 |
Annual Output2: |
15,000-30,000 kWh |
Head Weight (lbs): |
2,424 |
Mast Type: |
Tilt-Up, tapered, self-supporting, no guy wires |
Hub Height (ft): |
49 ft or 82 ft (taller towers also available upon request |
WT Found (yd3): |
21 or 65 |
Winch Found (yd3): |
3 (no anchor foundation for 82 ft) |
Tower Weight (lbs): |
3,258 or 6,160 |
Mechanical Brake: |
Yes |
| Noise3 @ 11 mph: | 48 dBA |
| Noise @ 45 mph: | 65 dBA |
| Rotor Thrust (kN): | 26 |
11 mile per hour = 13.6 kph = 0.45 metre/second.
Annual Output 2 range is quoted to cover typical average wind speeds (annual).
Lighter wind sites with typical 10 mph will produce lower end of range.
Higher wind speed sites, e.g., 13.5 mph average will produce upper end of range.
All readings taken with an ATP SL-25 dBA meter at the base of the
tower at a height of 5 ft.
A car passing 65 ft away @ approximately 40 mph is 70-80 dBA.